CyberPower OL6KRTF 6KVA/5.4KW, online double-conversion UPS, 6KW step-down transformer included
CyberPower OL6KRTF 6KVA/5.4KW, online double-conversion UPS, 6KW step-down transformer included
CyberPower OL6KRTF 6KVA/5.4KW, online double-conversion UPS, 6KW step-down transformer included
CyberPower OL6KRTF 6KVA/5.4KW, online double-conversion UPS, 6KW step-down transformer included
CyberPower OL6KRTF 6KVA/5.4KW, online double-conversion UPS, 6KW step-down transformer included

CyberPower

CyberPower OL6KRTF 6KVA/5.4KW, online double-conversion UPS, 6KW step-down transformer included

Sale price$6,399.00
SKU: OL6KRTF
Quantity:

The CyberPower Smart App Online OL6KRTF is a combined 8U with a 6U rack/tower double-conversion UPS and a 2U step-down transformer to support 120 V and 200-240 V output requirements. It provides sine wave output to multiple types of critical IT infrastructure requiring seamless power protection. Generator-compatible, the OL6KRTF delivers consistent output power with zero transfer time. Automatic-bypass ensures connected equipment continues to operate seamlessly when an overload or internal fault is detected.

The OL6KRTF features a removable LCD control panel to reposition it in a more convenient location (with optional DB-26 cable) and it has a RMCARD205 pre-installed network card. Smart Battery Management charging technology increases battery life by up to 50%. Fast Charge Technology helps replenish battery charge from 0-90% in four hours regardless of number of Extended Battery Modules (EBM) connected. The energy-saving GreenPower UPS™ ECO Mode allows the UPS to reach up to 96% efficiency to reduce power consumption and thermal dissipation.

This UPS can use the BP240V30ART3U or BP240VL3U01 Extended Battery Module for more runtime. The OL6KRTF comes with a three-year warranty (including batteries) and a $300,000 Connected Equipment Guarantee.

Double-Conversion Topology

  • Provides consistent, clean, and nearly perfect sine wave output power, regardless of the condition of input power. UPS systems with this technology operate on isolated DC power 100% of the time and have a zero-transfer time because they electronically switch to battery (vs. using relays which can take 4-12 ms to switch). Double-conversion UPS systems are designed for high-availability applications, precise output voltage regulation (±2%), generator set compatibility, environments with poor power quality, and other sensitive electronic equipment.

Sine Wave Output Provides power protection to ENERGY STAR® 6.0 systems with Active PFC power supplies.
Step-down Transformer

  • Converts 208V input voltage originating from utility power, a UPS, or a generator to 120V output. The included 6-foot cord (NEMA L6-30P plug to ROJ) connects the transformer to input power. Over temperature protection safeguards it from damage if the internal heat exceeds safe operating parameters.

Removable LCD Control Panel

  • Panel displays 24 UPS status readings and allows configuration of 27 operation settings. The onboard event log will record and display the five most recent UPS system events. The LCD control panel can be removed and mounted in a more convenient location, up to ten feet away from the UPS (with optional DB-26 cable). Users can manage, setup, and control various operation settings, users can scroll through multiple UPS status readings and run select UPS diagnostic tests.

Multiple Language Options

  • The LCD control panel can be configured to English, Spanish, French, or German for use in multiple countries.

Extended Battery Module (EBM)

  • Add runtime by connecting more EBMs. The Smart App Online series of UPS systems allow for up to ten EBMs to be connected in a daisy-chain.

Fast Charge Technology

  • Enables Smart App Online UPS systems with multiple EBMs to charge batteries from 0-90% capacity in four hours. This is possible thanks to the built-in charger in each EBM.

Smart Battery Management (SBM)

  • Extends the service life of Smart App Online UPS batteries and reduces excessive heat during charge cycles by using a three-stage charging process. The first stage charges the battery to full capacity. The second stage enters float mode. The third stage turns the charger OFF to allow the batteries to naturally discharge (rest) for up to 27 days or until they reach a low-voltage set point. SBM continuously monitors the UPS to restart the charge cycle as needed, ensuring that runtimes are maintained.

GreenPower UPS™ ECO Mode

  • Improves UPS efficiency up to 96% to reduce electrical and cooling costs.

Hot-Swappable Batteries

  • Eliminate downtime related to UPS maintenance for continuous power availability.

Generator Compatible

  • Mode of operation in which the UPS disregards rapid changes in input frequency like those found in the output waveform of some generator sets. This allows the UPS to continue to operate in normal Online Mode vs. switching to Battery Mode when the power source is a generator set.

Converter Mode

  • Provides the ability to set the UPS output frequency (50 Hz or 60 Hz), regardless of the input frequency. This is beneficial where the connected equipment must operate on a different frequency than provided by local electric utility.

Local and Remote Management

  • Monitor and manage the UPS system locally via USB or serial connection, or remotely via the pre-installed RMCARD205 network card. Access UPS status, configuration settings, event logs, and status records, and more. User can also setup email notifications.

Rack or Tower Installation

  • All the hardware accessories to rack mount the UPS in a standard 4-post 19” rack, or install as a tower unit, is included at no extra cost.

PowerPanel® Business Edition Software

  • A robust and feature rich power monitoring and management tool for physical or virtual environments, PowerPanel Business Edition offers local (Agent) or remote (Client) functionality to automate graceful shutdown of IT equipment. Installing PowerPanel Business Edition Center provides centralized monitoring and management of PPBE Agents and Clients on the local network in addition to all CyberPower devices. PPBE is FREE for download on the Downloads tab above.

Three-Year Warranty

  • CyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date.

Connected Equipment Guarantee

  • CyberPower will repair or replace properly connected equipment if it is damaged by a power surge.

What’s In The Box

6,000 VA UPS power module, Extended Battery Module, 2x Left & right rackmount rails, 2x Left & right hanging brackets, Phone cable, USB communication cable, Serial interface cable (RS-232), NEMA L6-30P to IEC-320-C13 power cord, Quick Start Guide, Safety instructions, Registration warranty card, PowerPanel Management Software Download Card, 4x Rackmount ears, (2) Tie plates, (24) Black M5X7L flat head screws, (36) Black M5X12L pan head screws, (18) Silver M5X6L pan head screws, (24) Plastic washers, (40) Screw hole dust covers, (36) Rubber pads, OL6KSTF 2U 6,000 VA Step-down and Isolation Transformer, 6 ft NEMA L6-30 locking male plug to 3-wire ROJ (remove outer jacket) power cable (L630PHW6FT), 2x Terminal block cable glands, Left & right rackmount rails, Left & right hanging brackets, Input/output terminal block cover, Quick Start Guide, Registration Card, 2U rack mount ears (tower stands), Safety Instruction Card


WARNING:

This product can expose you to chemicals including Styrene, which are known to the State of California to cause cancer, and Bisphenol A (BPA), which are known to the State of California to cause birth defects or other reproductive harm. For more information go to http://www.P65Warnings.ca.gov.

General
UPS Topology Double Conversion
Energy Saving Yes – ECO Mode Efficiency up to 96%
Input
Voltage 200 V to 240 V
Input Voltage Range 120 – 139 VAC for 0–25% load

140 – 159 VAC for 0–50% load

160 – 179 VAC for 0–75% load

180 – 280 VAC for 0–100% load

Frequency Range 40 Hz to 70 Hz (auto-sensing)
Input Power Factor 0.99
Cold Start Yes
Plug Type NEMA L6-30P
Cord Length 10 ft
Backfeed Protection Yes
Output
VA 6,000 VA
Watts 5,400 W
On Battery Voltage 120 V; 200, 208, 220, 230, 240 V ±2% (configurable)
On Battery Frequency 50/60 Hz ±0.25 Hz (auto-sensing/configurable)
On Battery Waveform Sine Wave
Outlet Type (6) NEMA 5-20R
(2) NEMA L6-20R
(1) NEMA L6-30R
(1) Hardwire Terminal Block
Outlets – Total 10
Rated Power Factor 0.9
Crest Factor 3:1
Harmonic Distortion <3% at linear load, <5% at non-linear load
ECO Mode Voltage Regulation ±10%, ±15% (configurable)
Bypass Internal Bypass (Automatic and Manual)
Overload Protection Line Mode: 105% to 125% load for 1 min, 126% to 150% load for 10 s

Battery Mode: 105% to 130% load for 10 s, 131% to 150% load for 2 s

Transfer Time 0 ms
Battery
Runtime at Half Load 15 min
Runtime at Full Load 5.4 min
Battery Type Sealed Lead-Acid
Battery Size 12 V/7 Ah
Battery Quantity 20
Hot-Swappable Yes
Replaceable Yes
Replacement Battery Cartridge (2) RB1270X10
Typical Recharge Time 4 h (0% to 90%)
Extended Battery Option Optional BP240V30ART3U or BP240VL3U01
Smart Battery Management (SBM) Mode Yes
Surge Protection & Filtering
Surge Suppression 2430 Joules, IEC 61000-4-5 Level 3
EMI/RFI Filtration Yes
Phone / Network Protection RJ11/RJ45 1-In / 1-Out
Management & Communications
LCD Control Panel Access 50 information status and configuration settings via the Information and Configuration Menus, in addition to an Event Log Menu.
Removable LCD Control Panel Option Yes – Requires DB26 cable (not included)
HID Compliant USB Port Yes
Serial Port Yes
EPO Port Yes
Dry Contacts Yes
Cables Included USB cable, serial cable, phone cable
LED Indicators Power On (White)
Line Mode (Green)
Battery Mode (Yellow)
Bypass Mode (Yellow)
Fault (Red)
Replace Battery (Red)
Audible Alarms Battery Mode
Battery Low
Overload
UPS Fault
Software PowerPanel® Business Edition
Expansion Slot Yes – RMCARD205 pre-installed
Physical
Form Factor Rack/Tower
Enclosure Construction Steel
Rack Mounting Hardware Included
Dimensions – W×H×D (in) 17 x 14 x 26
Weight (lbs) 316.6
Rack Units 8U
Max. Mounting Rail Depth (in.) 36.02
Min. Mounting Rail Depth (in.) 20.47
Shipping Dimensions – WxHxD (in) 23.62 x 38.1 x 35.43
Shipping Weight (lbs) 410 lbs
Environmental
Operating Temperature 32 °F to 104 °F (0 °C to 40 °C)
Operating Relative Humidity 0% to 90% non-condensing
Operating Elevation 0 ft to 10,000 ft (0 to 3,000 m)
Storage Temperature -4 °F to 113 °F (-20 °C to 45 °C)
Storage Relative Humidity 0% to 95% non-condensing
Storage Elevation 0 ft to 50,000 ft (0 m to 15,000 m)
STF Thermal Dissipation (100% load) 1379 BTU/hr
ECO Mode Thermal Dissipation (100% Load) 728 BTU/h
Online Thermal Dissipation (100% Load) 1912 BTU/h
Audible noise at 1m from surface of unit 38 dBA to 65 dBA (0% to 100% load)
Certifications
Safety UL 1778 5th Ed.
CSA C22.2 NO.107.3-05
FCC Part 15 Class A
Environmental RoHS Compliant
Warranty
Product Warranty 3 Years Limited
Extended 2-Year Warranty Optional WEXT5YR-U20B
Connected Equipment Guarantee Lifetime
CEG Amount $300,000